Diesel generator set - YUCHAI BC-YC113D-60B (90 kW / 113 kVA)
BOCHI POWER Yuchai gensets use electronically injected Yuchai engines with good response to varying loads and widely available spare parts in the region. Integrated and tested by BOCHI POWER.
| Model | BC-YC113D-60B |
| Standby power | 113 kVA / 90 kW |
| Prime power | 100 kVA / 80 kW |
| Engine | YC6B160Z-D20 |
| Frequency | 60 Hz |
| Voltage | Multi-voltage 110/208 - 277/480 V |
| Phases | Three-phase, four-wire |
| Dimensions (mm) | 1900 x 750 x 1100 |
| Type | Open set |
Built, integrated and tested by BOCHI POWER.
Overview
A Diesel Generator Set - YUCHAI BC-YC113D-60B (90 kW / 113 kVA) standby rating defines the BC-YC113D-60B, a diesel genset built around a YC6B160Z-D20 engine, open type configuration, set for 50/60 Hz and three-phase four-wire, at 110/208 V – 277/480 V.
This is the usual backup rating for a commercial site or a small industrial unit: it carries the essential load without oversizing the installation, and leaves headroom for motor and compressor starting. BCP’s Yuchai range spans 23 to 3750 kVA with Yuchai power, intended for standby duty and for extended running depending on how the fuel and cooling system is specified.
Typical applications
- Small industrial units and production workshops
- Hotels and shopping centres
- Clinics and diagnostic centres
- Pumping and water treatment systems
- Construction sites and temporary camps
Standby and prime ratings
The standby rating (113 kVA / 90 kW) is what the set delivers during a grid outage, for a limited number of hours a year and without sustained overload. The prime rating (PRP) allows continuous duty with varying load. Sizing starts from the real load in kW, corrected by power factor, with headroom left for motor starting.
Frequently asked questions
What is the difference between standby and prime?
Standby is the power available in an emergency, limited to a set number of hours a year; prime is what the set can sustain continuously with varying load. A set sized for standby should not be used as prime generation without re-checking the duty.
What voltage and connection does the BC-YC113D-60B deliver?
It is offered at 110/208 V – 277/480 V, three-phase four-wire, 50/60 Hz. Final nameplate voltage is fixed at order stage according to the site network and the transfer arrangement.
How much headroom should be left above the real load?
Allow 20–25 % above the measured load in kW to absorb motor starting and to keep the set from running continuously above 80 % of its rating.
More from the range
Full Yuchai range: Yuchai diesel generator sets · all series and ratings · generator set catalogue · request a quote.
Similar power ratings
- BC-YC113D-60A — 113 kVA
- BC-YC165D-60A — 165 kVA
- BC-YC165D-60B — 165 kVA
- BC-YC296D-60 — 296 kVA
Specifications
| Characteristics | |
|---|---|
| Brand | YUCHAI |
| Engine Model | YC6B160Z-D20 |
| Voltage (V) | 110/208V 127/220V 230/400V 254/440V 277/480V |
| Power (kW) | 90 |
| Emission Standards | T 2 |
| Phases | Three-phase four-wire system |
| Generator Set | |
|---|---|
| Generator set model | BC-YC113D-60B |
| Generator set series | Diesel series |
| Generator set structure type | Open type |
| Others | |
|---|---|
| Rating (kVA) | 113 |