Skip to Content

Diesel generator set - CUMMINS BC-DC425D-60 (340 kW / 425 kVA)

https://generator.bochipower.com/web/image/product.template/16050/image_1920?unique=dfb95f6
(0 review)

BOCHI POWER Cummins gensets use genuine Cummins engines with PT fuel injection and an alloy steel crankshaft and connecting rods. Engine, alternator and control are built, tested and reviewed by BOCHI POWER, which keeps starting reliable, fuel consumption low and service life long.

ModelBC-DC425D-60
Standby power425 kVA / 340 kW
Prime power388 kVA / 310 kW
Engine6ZTAA13-G3
Frequency60 Hz
VoltageMulti-voltage 110/208 - 277/480 V
PhasesThree-phase, four-wire
Dimensions (mm)2900 x 1200 x 1700
TypeOpen set

Built, integrated and tested by BOCHI POWER.

$ 31,413.77 31413.77 USD Tax Excluded

31,413.77 Bs Tax Excluded

  • Brand
  • Engine Model
  • Voltage (V)
  • Power (kW)
  • Emission Standards
  • Phases
  • Generator set model
  • Generator set series
  • Generator set structure type
  • Rating (kVA)

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Overview

The Diesel Generator Set - CUMMINS BC-DC425D-60 (340 kW / 425 kVA) is a 425 kVA / 340 kW standby diesel generator set, built around a 6ZTAA13-G3 engine and open type configuration. It delivers 60 Hz, three-phase four-wire, at 110/208 V – 277/480 V.

This rating is used as whole-plant backup or as on-site prime generation: mid-size industrial plants, distribution centres and infrastructure projects whose base load exceeds what a compact set can carry. BCP’s Cummins range spans 28 to 2090 kVA with Cummins power, intended for standby duty and for extended running depending on how the fuel and cooling system is specified.

Typical applications

  • Mid-size industrial plants
  • Distribution centres and cold storage
  • Mining and quarries
  • Infrastructure projects
  • On-site generation for remote plants

Standby and prime ratings

The standby rating (425 kVA / 340 kW) is what the set delivers during a grid outage, for a limited number of hours a year and without sustained overload. The prime rating (PRP) allows continuous duty with varying load. Sizing starts from the real load in kW, corrected by power factor, with headroom left for motor starting.

Frequently asked questions

What is the difference between standby and prime?

Standby is the power available in an emergency, limited to a set number of hours a year; prime is what the set can sustain continuously with varying load. A set sized for standby should not be used as prime generation without re-checking the duty.

What voltage and connection does the BC-DC425D-60 deliver?

It is offered at 110/208 V – 277/480 V, three-phase four-wire, 60 Hz. Final nameplate voltage is fixed at order stage according to the site network and the transfer arrangement.

Can it run in parallel with another set or with the grid?

Yes, with a synchronising panel and coupling protection. Parallel operation requires agreeing load-sharing modes, protection settings and the transfer sequence before the panel is built.

More from the range

Full Cummins range: Cummins diesel generator sets · all series and ratings · generator set catalogue · request a quote.

Similar power ratings

Specifications

Characteristics
Brand CUMMINS
Engine Model 6ZTAA13-G3
Voltage (V) 110/208V 127/220V 230/400V 254/440V 277/480V
Power (kW) 340
Emission Standards T 2
Phases Three-phase four-wire system
Generator Set
Generator set model BC-DC425D-60
Generator set series Diesel series
Generator set structure type Open type
Others
Rating (kVA) 425