29 configurations from 22 to 889 kVA. SDEC engines with Stamford alternator and matched control panel for prime and standby duty.
Specifications
Available models
| Alimentado por SDEC | 400V, 1500RPM, 50Hz | |||||||
|---|---|---|---|---|---|---|---|
| Modelo Bochi Power | kVA En Espera | kVA Principal | Modelo Motor | Alternador Stamford | Dimensión mm Tipo Abierto | Dimensión mm Tipo Insonorizado | PDF de Datos |
| BC-SH26 | 26 | 23 | 4Z2.3-G12 | S0L2-M1 | 1760*760*1380 | 2290*1060*1680 | — |
| BC-SH32 | 32 | 29 | 4Z2.7-G12 | S0L2-P1 | 1760*760*1380 | 2290*1060*1680 | — |
| BC-SH37 | 37 | 33 | 4Z2.0-G12 | S1L2-X1 | 1760*760*1380 | 2290*1060*1680 | — |
| BC-SH47 | 47 | 42 | 4Z2.2-G12 | S1L2-Y1 | 1760*760*1380 | 2440*1060*1680 | — |
| BC-SH51 | 51 | 46 | 4ZT2.2-G12 | S1L2-Y1 | 1760*760*1380 | 2440*1060*1680 | — |
| BC-SH67 | 67 | 61 | 4ZT3.5-G21 | UCI 224F1 | 1760*760*1380 | 2440*1060*1680 | — |
| BC-SH76 | 76 | 69 | 4HT4.3-G21 | UCI 224G1 | 1760*760*1380 | 2600*1060*1680 | — |
| BC-SH82 | 82 | 75 | 4HT4.3-G22 | UCI 224G1 | 1760*760*1380 | 2810*1140*1830 | — |
| BC-SH86 | 86 | 78 | 4ZT4.1-G21 | UCI 274C1 | 2300*830*1700 | 2810*1140*1830 | — |
| BC-SH106 | 106 | 96 | 4HT4.3-G23 | UCI 274H1 | 2450*960*1850 | 3590*1150*2050 | — |
| BC-SH129 | 129 | 117 | 4HTAA4.3-G21 | UCDI 274K1 | 2500*1200*1850 | 3590*1310*2050 | — |
| BC-SH147 | 147 | 133 | 4HTAA4.3-G23 | S4L1D-D41 | 2500*1150*1850 | 3890*1460*2150 | — |
| BC-SH167 | 167 | 152 | 6HTAA6.5-G21 | S4L1D-D41 | 2500*1150*1850 | 3890*1460*2150 | — |
| BC-SH183 | 183 | 167 | 6HTAA6.5-G22 | S4L1D-G41 | 3400*1258*2050 | 4630*1660*2250 | — |
| BC-SH220 | 220 | 200 | 6HTAA6.5-G23 | HCI 544CI | 3400*1258*2050 | 4630*1660*2250 | — |
| BC-SH251 | 251 | 228 | 6DTAA8.9-G21 | UCDI 274K1 | 3020*1100*1850 | 3890*1460*2150 | — |
| BC-SH278 | 278 | 253 | 6DTAA8.9-G24 | S5L1D-C4 | 3400*1258*2050 | 4630*1660*2250 | — |
| BC-SH313 | 313 | 285 | 6DTAA8.9-G23 | HCI644E1 | 3650*1638*2050 | 5030*1860*2550 | — |
| BC-SH376 | 376 | 341 | 6ETAA11.8-G21 | HCI 544F1 | 3650*1638*2050 | 5030*1860*2550 | — |
| BC-SH450 | 450 | 409 | 6ETAA12.8-G22 | S5L1D-E4 | 3650*1638*2050 | 5030*1860*2550 | — |
| BC-SH489 | 489 | 444 | 6ETAA12.8-G31.1 | S5L1D-H4 | 4550*2100*2320 | Contenedor ISO 20'GP | — |
| BC-SH500 | 500 | 455 | 6ETAA12.8-G310.1 | S6L1D-C4 | 4550*2100*2320 | Contenedor ISO 20'GP | — |
| BC-SH562 | 562 | 511 | 6KTAA25-G36.1 | S6L1D-D4 | 4550*2100*2320 | Contenedor ISO 20'GP | — |
| BC-SH611 | 611 | 556 | 6KTAA25-G311 | S6L1D-E4 | 4750*2100*2320 | Contenedor ISO 20'GP | — |
| BC-SH636 | 636 | 578 | 6KTAA25-G35.1 | S6L1D-F4 | 4750*2100*2320 | Contenedor ISO 20'GP | — |
| BC-SH699 | 699 | 635 | 6KTAA25-G34.1 | S6L1D-G4 | 5000*2200*2500 | Contenedor ISO 20'GP | — |
| BC-SH760 | 760 | 691 | 6KTAA25-G33.1 | S7L1D-C4 | 5820*2200*2800 | — | — |
| BC-SH838 | 838 | 762 | 6KTAA25-G32.1 | S7L1D-C4 | 5820*2200*2800 | Contenedor ISO 20'GP | — |
| BC-SH889 | 889 | 808 | 6KTAA25-G31.1 | S7L1D-E4 | 5820*2200*2800 | Contenedor ISO 20'GP | — |
| Powered by SDEC | 220V, 440V, 480V, 1800RPM, 60Hz | |||||||
|---|---|---|---|---|---|---|---|
| Bochi Power Model | kVA Standby | kVA Prime | Engine Model | Stamford Alternator | Dimension mm Open Type | Dimension mm Silent Type | Data Sheet |
| BC-SH22D-60 | 22 | 20 | — | — | — | — | — |
| BC-SZ28D-60 | 28 | 25 | — | — | — | — | — |
| BC-SH33D-60 | 33 | 30 | 4Z2.7-G12 | S0L2-P1 | 1760*760*1380 | 2290*1060*1680 | — |
| BC-SH44D-60 | 44 | 40 | 4Z2.2-G12 | S1L2-Y1 | 1760*760*1380 | 2440*1060*1680 | — |
| BC-SZ48D-60 | 48 | 44 | — | — | — | — | — |
| BC-SZ66D-60 | 66 | 60 | — | — | — | — | — |
| BC-SH69D-60 | 69 | 63 | 4ZT3.5-G21 | UCI 224F1 | 1760*760*1380 | 2440*1060*1680 | — |
| BC-SH76D-60 | 76 | 69 | 4HT4.3-G21 | UCI 224G1 | 1760*760*1380 | 2600*1060*1680 | — |
| BC-SZ77D-60 | 77 | 70 | — | — | — | — | — |
| BC-SH83D-60 | 83 | 75 | 4HT4.3-G22 | UCI 224G1 | 1760*760*1380 | 2810*1140*1830 | — |
| BC-SH88D-60 | 88 | 80 | 4ZT4.1-G21 | UCI 274C1 | 2300*830*1700 | 2810*1140*1830 | — |
| BC-SH124D-60 | 124 | 113 | 4HTAA4.3-G21 | UCDI 274K1 | 2500*1200*1850 | 3590*1310*2050 | — |
| BC-SH138D-60 | 138 | 125 | 4HTAA4.3-G23 | BCP-274D (126 kW / 157.5 kVA) | 2500*1150*1850 | 3890*1460*2150 | — |
| BC-SH165D-60 | 165 | 150 | 6HTAA6.5-G21 | S4L1D-D41 | 2500*1150*1850 | 3890*1460*2150 | — |
| BC-SH182D-60 | 182 | 165 | 6HTAA6.5-G22 | S4L1D-G41 | 3400*1258*2050 | 4630*1660*2250 | — |
| BC-SH206D-60 | 206 | 187 | 6HTAA6.5-G23 | HCI 544CI | 3400*1258*2050 | 4630*1660*2250 | — |
| BC-SH242D-60 | 242 | 220 | 6DTAA8.9-G21 | UCDI 274K1 | 3020*1100*1850 | 3890*1460*2150 | — |
| BC-SH275D-60 | 275 | 250 | 6DTAA8.9-G24 | S5L1D-C4 | 3400*1258*2050 | 4630*1660*2250 | — |
| BC-SH303D-60 | 303 | 275 | 6DTAA8.9-G23 | HCI644E1 | 3650*1638*2050 | 5030*1860*2550 | — |
| BC-SH385D-60 | 385 | 350 | 6ETAA11.8-G21 | HCI 544F1 | 3650*1638*2050 | 5030*1860*2550 | — |
| BC-SH413D-60 | 413 | 375 | — | — | — | — | — |
| BC-SH440D-60 | 440 | 400 | 6ETAA12.8-G22 | S5L1D-E4 | 3650*1638*2050 | 5030*1860*2550 | — |
| BC-SH550D-60 | 550 | 500 | 6KTAA25-G36.1 | S6L1D-D4 | 4550*2100*2320 | Contenedor ISO 20'GP | — |
| BC-SH622D-60 | 621 | 565 | 6KTAA25-G311 | S6L1D-E4 | 4750*2100*2320 | Contenedor ISO 20'GP | — |
| BC-SH633D-60 | 633 | 575 | 6KTAA25-G35.1 | S6L1D-F4 | 4750*2100*2320 | Contenedor ISO 20'GP | — |
| BC-SH684D-60 | 683 | 622 | 6KTAA25-G34.1 | S6L1D-G4 | 5000*2200*2500 | Contenedor ISO 20'GP | — |
| BC-SH743D-60 | 743 | 676 | 6KTAA25-G33.1 | S7L1D-C4 | 5820*2200*2800 | NA | — |
| BC-SH820D-60 | 819 | 745 | 6KTAA25-G32.1 | S7L1D-C4 | 5820*2200*2800 | Contenedor ISO 20'GP | — |
| BC-SH870D-60 | 869 | 791 | 6KTAA25-G31.1 | S7L1D-E4 | 5820*2200*2800 | Contenedor ISO 20'GP | — |
— = not supplied by the engine manufacturer.
FAQ
Six questions buyers ask
about selection and delivery
Not covered here? Tell us the project conditions and an engineer will come back with a recommendation.
Talk to an engineerCan you build a configuration for our project?
Yes. Send the power requirement, voltage and frequency, duty (prime or standby) and the installation conditions to mktg@bochipower.com, and we will come back with a selection and configuration proposal.
How long does a design proposal take?
Once the parameters are complete we start the selection right away, and standard configurations are answered first. Non-standard work — paralleling, soundproofed or containerised sets, special voltages — is quoted after engineering review.
How many years have you been building this equipment?
32 years, working only on diesel generator sets.
Which certifications do the units carry?
CE and ISO, plus OEM certification for CUMMINS, VOLVO PENTA, MTU, PERKINS, BAUDOUIN, YUCHAI, WEICHAI, SDEC, DOOSAN and MITSUBISHI.
What should we include in an enquiry?
The model or power range, voltage and frequency, open / soundproofed / containerised, quantity and delivery port. The more complete the enquiry, the faster the quotation.
Still have a question?
Write to mktg@bochipower.com, or leave your requirement on the contact page, and the colleague for your region will follow up.
Engineering & supply
Need a tailored configuration?
Tell us the rating, the voltage and the site conditions. We come back with a technical and commercial proposal within the shortest possible lead time.
Request a quote