Generator controller - ATS ATS530

https://generator.bochipower.com/web/image/product.template/1003/image_1920?unique=2c28dc4
(0 review)
El controlador de conmutación automático de la fuente de alimentación de doble carretera ATS530NC está compuesto por microprocesadores como su núcleo, que puede detectar con precisión el voltaje de dos fases y el voltaje de una sola fase de dos vías. Frecuencia, falta de fase, fase inversa) hacer juicios precisos y controlar el cambio de ATS después del retraso. 

$ 119.75 119.75 USD Tax Excluded

119.75 Bs Tax Excluded

  • Brand
  • Model
  • Dimensions
  • Weight
  • Country of Origin

This combination does not exist.

Controller

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Controller - ATS ATS530 switches the load between mains and generator: it monitors the mains, commands the start, transfers, and re-transfers with a delay so the set is not shocked.

In contactor-based ATS the wear is in the main contacts and the mechanical interlock. In motorised-breaker ATS it is the charging motor and the limit switches. Knowing which one your panel uses tells you what to keep in stock.

Specifications and compatibility

Brand
BCP
Model
ATS530 RS485
Dimensions
150 x 130 x 75 mm
Weight
1.00 kg
Country of origin
China

How to verify before ordering

  • Match the number of poles, the rated current and the switching type (contactor or motorised breaker).
  • Check the ATS control voltage: 110 V, 220 V or 24 V depending on the panel it goes into.
  • Confirm whether neutral is switched. On installations with a distributed neutral this is mandatory.
  • The reference shown on this listing is ATS530 RS485; cross-check it against the one stamped on the removed part.
  • Declared origin: China. Check this if your purchase requires a specific origin.

Frequently asked questions

The set starts but the load is not transferred. What do I check?

The signal first: mains-sensing relay, control fuse and the wiring between ATS and set. Then the interlock: if the mains contactor does not release, the generator contactor will not close, by design.

Can I fit an ATS of another brand?

Yes, as long as control voltage and logic are compatible with the set panel. With a controller-based set, the ATS must accept that controller transfer signal.

Related parts

See the spare parts catalogue or request a quotation quoting the equipment reference. Third-party trademarks are cited for identification purposes only.

Specifications

Model ATS530 LINK, ATS530 RS485
Brand BCP
Dimensions 150 x 130 x 75 mm
Weight 1,00 kg
Country of Origin China
Tags
Tags
Controller